Cement filled steel box floor system anti-static raised panel raised floor

Product Detail

Single package size:70X70X20 cmcolor:Can be customized according to customer requirements
Packaging Details:Two pieces in one carton, 60 pieces in one wooden boxAfter-sales service:Online technical support, free spare parts, online training
Package preview:Warranty:2 years
HPL veneer thickness:1.2mm thickness optionthing:JQGH-2AaB type all steel access floor
final load:≥5880NUniform load:≥9760 N per square meter
Floor Thickness:35MM thicknessOrigin:Shaanxi, China
Sales unit:single productapplication:computer room server center data center
model:JQGH-2AaBCertificate:ISO9001+OHSAS+GB/T28001-2011+ISO14001
Project solution ability:Project overall solution, cross-category integration, othersMaterial:All steel, cement, HPL
Concentrated load:LB≥440, N≥1960, KG≥200Covering material:Conductive HPL finish
Accessories:with base, beam and screwsGross weight per piece:20.000 kg
brand:Wisdomdesign style:traditional
Cement filled steel box floor system anti-static raised panel raised floor

All steel raised raised floor with HPL veneer
- All steel structure
- High quality HPL veneer
- Filled with advanced foam cement
- Using high-quality deep-drawn coiled steel plate as the bottom surface
- Using SPCC steel plate as the top surface
- Conductive trim all around
- The base is pressed from steel plate
- screw height adjustable
- The beams are made of high quality square tubes
serial number.
National standard
Specifications (mm)
JQGH-1
HDG.600.35.CQ.D
600X600X35
JQGH-2
HDG.600.35.QD
600X600X35
JQGH-3
HDG.600.35.BD
600X600X35
JQGH-4
HDG.600.35.ZD
600X600X35
Item No.: JQGH-1
Concentrated load (LB≥440, N≥1960, KG≥200)
Impact load ≥ 295 N
Ultimate load≥5880 N
Uniform load ≥ 9720 N
Rolling load ≥ 1960 N

Item No.: JQGH-2
Concentrated load (LB≥662, N≥2950, ​​KG≥301)
Impact load ≥ 445 N
Ultimate load≥8850 N
Uniform load ≥ 12500 N
Rolling load ≥ 2950 N

Item No.: JQGH-3
Concentrated load (LB≥1000, N≥4450, KG≥450)
Impact load≥670 N
Ultimate load ≥ 13350 N
Uniform load ≥ 23000 N
Rolling load ≥ 3560 N

Item No.: JQGH-4
Concentrated load (LB≥1250, N≥5560, KG≥567)
Impact load ≥ 780
Ultimate load ≥ 16680
Uniform load ≥ 33000
Rolling load ≥ 4450
The bottom surface of the floor is made of high-quality deep-drawn coiled steel plate, and the rigidity of the top surface is made of SPCC steel plate; the connection between the top steel plate and the bottom steel plate should be formed by stamping and spot welding; then the outside should be treated with phosphating and plastic spraying; Soak cement and form a stable support structure after a period of time; the top steel plate is covered with wear-resistant and anti-static HPL veneer. Then the floor should be installed with brackets, beams, screws

Advantage
Specializing in the production of anti-static floor for more than 30 years with good quality
- fire performance
- sound insulation
- Manufactured with high precision
- easy to install
- good interchangeability
- The installation height can be adjusted arbitrarily
All-steel access floor can be matched with ceramic veneer, PVC veneer, HPL veneer, granite veneer


our company
In 1990, we produced the first anti-static floor. Xi'an Zhihui Computer Room Equipment Co., Ltd. is a professional manufacturer engaged in the design, research and development, production, sales and installation of various anti-static raised floors, such as anti-static steel structure activities in computer rooms Floor, OA mesh floor, clean room conductive raised floor, airflow raised floor, calcium sulfate raised floor, wood core board, aluminum anti-static raised floor, etc.

We have advanced production equipment, mature production technology, strong technical research and development, product development, mass production, sales, installation and other teams;

Our company strength:
A: Registered capital: RMB 67 million
B: Factory area: covers an area of ​​more than 40 acres
C: Production line: 10
D: Product categories: more than 100 kinds
E: Annual production capacity: more than 1.5 million square meters

our certificate
We have passed ISO9001, ISO14001, OHSAA8001 certification.
Produced in strict accordance with SJ/T10796-2001 standard,Comply with CISCA, CE, MOB international standard certification

Our product application
Computer center; Communication center; Data center; Radio and television transmission center; Power control dispatch center; Microwave communication station; Satellite ground station; Mobile center;
B. Electronic and optical equipment production workshops; hospital operating rooms; anesthesia rooms; electronic imaging inspection rooms; other places sensitive to static electricity.
C. Inflammable and explosive places such as military industry and petrochemical industry.
D Civic center; star hotel; smart office and other high-end places

our export market
We have stable quality and beautiful appearance; exported to Japan, South Korea, Singapore, Malaysia, the United States, the Middle East, Europe and other countries and regions; long-term service in domestic computer room decoration engineering companies, integrators, purification engineering companies, real estate developers, Won the praise of the majority of customers.


FAQ
What is your packing condition?
Usually, we pack 2pcs flooring in one carton, and then pack 60pcs in one wooden pallet for shipping container.

What are your payment terms?
30% deposit should be paid before mass production, 70% balance should be paid before shipment

What are your terms of delivery?
EXW, FOB, CIF, CFR at Shanghai port, Tianjin port and other ports in China

How about your delivery time?
Products in stock: normal items, it will take 1-2 days after receiving your deposit.
Customized products: depends on the quantity you need, generally 10-15 days after receiving your advance payment, large quantity needs to be negotiated

Do you test all your goods before delivery?
Our QC test all goods at production time and before shipment

Can you provide samples?
Yes, we can provide one free sample, two samples, you only need to pay the shipping cost

What certification do you have?
ISO14001:2015, OHSAS 18001:2007, ISO9001:2015

our production line
It has more than ten floor production lines such as calcium sulfate floor production line and all-steel alloy floor production line; aluminum alloy floor production line; net floor production line, etc. We produce strictly according to SJ/T10796-2001 standard.

maintenance and use
The room temperature for laying the anti-static floor is controlled at 15°C-35°C; the humidity is controlled at 45%-75%RH; if the computer room is in a high temperature or low humidity state for a long time, the floor surface will peel or break.
1. It is forbidden to use sharp tools to operate directly on the floor to prevent damage to the anti-static performance and aesthetics of the surface;
2. During use, it is strictly forbidden for personnel to jump directly from a height to the floor.
3. When moving the equipment on the floor, it is strictly forbidden to push the equipment directly on the board to scratch the floor. The correct way is to lift the equipment for handling
4. When there is heavy equipment in the machine room, the equipment should be placed directly on the ground base, not directly on the floor, causing long-term load-bearing deformation of the floor;
5. When maintaining the equipment under the floor, the floor is sucked up by the plate lifter for operation. It is forbidden to use sharp tools for brutal disassembly.
6. For maintenance, use a vacuum cleaner or a semi-dry mop to keep the floor clean, especially do not spill liquid on the floor.
7. The computer room is suitable for humidification in autumn and winter, and the floor surface is regularly maintained with anti-static wax to ensure the long-term use of the floor.

Precautions in USE
1. Site environmental requirements.
Temperature: 10-30°C
Relative humidity: RH 30-70%;
Temperature change rate: △Tw15℃/hour, or no condensation;
Vibration: no sustained vibration (source);
Chemical environment: no volatile substances, no highly corrosive substances
2. It is strictly forbidden to wash the surface of the elevated floor with water, and mop the floor with a wrung mop to prevent the surface of the elevated floor from peeling and the lower metal parts from scaling
3. Do not use hard objects (or sharp objects) to squeeze, hit, scratch, paint or paint plastic
4. When opening or installing the access floor, use a special panel lifter to handle it gently, and do not use hard pry iron.
5. Places with many people, such as corridors and entrances, should avoid overloading, otherwise the floor will be easily damaged.
6. For long-term heavy load, when the weight of a support point of the machine is greater than 1/3 of the load-bearing level of the floor, a column support should be added to the corresponding part of the floor, otherwise the floor will be easily deformed.
7. After the floor is laid, there may be noise when walking, which is related to the floor and installation, and has nothing to do with the performance of the floor itself.
8. Do not use heavy objects that may damage the floor.
9. Do not modify the floor at will. Do not move the panel lifters while the panel lifters are sucking the floor to prevent them from falling on the floor
Way. When shooting the floor, you should wear gloves, otherwise it will easily hurt your hands, and avoid direct sunlight, so as to avoid premature discoloration and aging of the finish layer.
10. Do not lay gas and water pipes under the floor.

Installation diagram

our case
VIEW MORE

Related Products